| Brand | Sosen | Model | HL12K-P3EU |
|---|---|---|---|
| Rated Power | 12 kW | Max PV Input Power | 24 kW |
| Max Charging Current | 250 Adc | MPPT Voltage Range | 150 ~ 950 Vdc |
| Nominal Output Voltage | 380 / 400 V a.c., 3W+N+PE | Nominal Output Frequency | 50 / 60 Hz |
| Nominal Voltage | 40 ~ 60 V | Number of MPPT Trackers | 2 / 2+2 |
| Product Dimensions | 448 x 660 x 265 mm | Product Weight | 35 kg |
| Communication | RS485 / WiFi / CAN / DRM (Optional: Bluetooth / LAN / Meter) | Efficiency | 97.50% |
| Operating Temperature | -25°C to +60°C (linearly derating to 60% when exceed +45°C to +60°C) | AC Output Rated Current | 17.4 Aac |
| Battery Type | Lithium / Lead-acid | Certification | EN IEC 62477-1, EN IEC 62109-1/2, EN IEC 61000-6-2, EN IEC 61000-6-4, EN50549-1/10 |
| Current Rating | 35/17 A | Display | LCD + App |
| Humidity | 0-95% (non-condensing) | Ingress Protection | IP66 |
| Max PV Input Current | 4*20 Adc | Max. AC Input/Output Apparent Power (VA) | 12 kVa |
| Max. PV short circuit current | 4*30 Adc | Maximum input voltage | 1000 Vdc |
| Maximum output current | 35 / 17 Aac | Noise | <40 dB |
| Parallel Operation | Yes | Permissible Altitude | 4000 m (>2000 m derating) |
| Power Factor | 0.8 leading ~ 0.8 lagging | Protection | Output over voltage, Output over current, Short circuit, Surge, Temperature, Anti-islanding |
| SKU | SM-THR-SOS-01395 | Start Voltage | 180 Vdc |
| Storage Temperature | 25°C to +60°C | Transfer Time | <20 ms |
Notice a wrong or outdated datasheet? Help us fix it.
The Sosen HL12K-P3EU is a three-phase hybrid inverter rated 12 kW / 12 kVA at 380/400 V a.c. (3W+N+PE, 50/60 Hz). It works with a low-voltage battery bank of 51.2 V nominal — the 40–60 V range covers both lithium and lead-acid types — charging at up to 250 Adc and discharging at up to 250 Aac, with three battery inputs available. On the solar side it accepts a PV array of up to 24 kW with a 1000 Vdc maximum input voltage and a 150–950 Vdc MPPT window across two MPPT trackers (2+2 strings), and it can be paralleled up to 8 units.
It is aimed at homes, shops, farms and small businesses that run three-phase equipment and need to keep working through grid outages. Changeover to backup takes under 20 ms, and the off-grid output handles 200% overload for 10 s plus 150% unbalanced three-phase loads, so pumps, fridges and motors start without tripping. The IP66 enclosure allows outdoor installation, AC coupling is supported for retrofitting an existing installation, and an LCD with app monitoring reports status over RS485, WiFi, CAN or DRM.